Non Intrusive Maintenance Switchboard

Non-Intrusive Maintenance

Non-intrusive maintenance techniques for switchgear and transformers are increasingly common owing to the development of testing devices such as partial discharge monitors and thermal cameras. Non-intrusive maintenance/inspections of your electrical plant cannot be used as a replacement to intrusive maintenance but is an increasingly essential activity.

 

Typical non-intrusive checks may include:

  • Visual Substation inspection
  • Partial discharge assessment
  • Earthing assessment
  • Thermal Surveys
 

Partial Discharge Survey:

What Is It?

Partial discharge activity is an electrical discharge or spark that occurs within the insulation between two conducting electrodes. Partial discharge generally develops over a period of time and can eventually lead to a disruptive failure of a cable termination, HV switchgear or transformer or other component.


What Does The Survey Involve?

Lucy Electric’s trained engineers utilise the most up to date locators to assess for partial discharge on your site. We will not need to shut the power down for these tests and will provide a report
afterwards which details our findings and any recommendations. Partial discharge assessment is not a substitute for an ongoing maintenance regime that incorporates intrusive (shutdown) and non-intrusive (no shutdown) maintenance but it does give a very good indication of any potential areas of failure. The device that we utilise is portable which means we can access any substation in any location. Our skilled team of engineers will be happy to give you a demonstration on site should you wish to know more.

 

Thermal Surveys

Thermal surveys involve the use of an infra-red camera to detect ‘hot-spots’ within a component (ACB / MCCB / Contactor for example) or a cable/busbar connection or conductor. If a connection/conductor is operating at an increased temperature than standard recommendations it
is generally a sign that there is a potential loose connection or overloading of the circuit. If not rectified this ‘hot-spot’ can develop into a fault that could result in a loss of power to that circuit until a repair can be completed.

 

What Does The Survey Involve?

Lucy Electric’s skilled team of engineers can attend site to complete a survey of your equipment. This would typically involve the completion of this survey during the daytime as the majority of sites operate at a higher loading profile during office hours. The survey can be complete anytime should your loading profile dictate. Once the survey is completed you will expect to receive a detailed report which will include thermal and standard images to detail any areas of concern. A table of recommendations will include any specific circuits / equipment that require further action. Lucy Electric’s engineers can then assist you with any remedial actions where required. Following the visit we will analyse the results of all tests and surveys and provide a detailed report containing photographs with a list of recommendations for remedial actions.

 

Typical Report Content

Following the works on site our site team will upload the photographs to our specific software and review each image before providing a set of condition comments and a set of recommendations for remedial action.

 

Relevant Information

As well as being able to purchase the below documents, the Health & Safety Executive (HSE) publishes some very relevant guidance documents on their website.

 

If you wish to know more, please contact our energy services team:

Address:
Lucy Electric,
Howland Road,
Thame,
Oxon,
OX9 3UJ

Email: energyservices@lucyelectric.com
Tel:     +44 (0) 1844267267

Registered No. 1179461 England | © Lucy Electric 1999-2017